MIRMgate is a not for profit initiative of the University of Queensland to provide the minerals industry with comprehensive safety information.



F.E.A.S. Canister Fire Suppression System Failure

Click here to view resource.

     Click a tab to view specific information about this listing...
  • COMPLIANCEgate

Information:

In order to work on the fire detection panel of a dragline fitted with a FEAS Canister fire suppression system, a technician powered the system down by disconnecting the backup batteries and isolating the 240-volt supply. At this time the dragline lost power and upon investigation it was found that the FEAS canisters in the slip ring enclosure had discharged and an electrical flashover of the 6.6 KV slip rings to earth had occurred. Furthermore, the canisters had not discharged through the coolant in the correct manner but had burned holes in the sides of the canisters.



Organisation:

Department of Natural Resources and Mines

Click here to view details and other documents from Department of Natural Resources and Mines.


Jurisdiction:

Relates to Queensland (QLD)

Click here to view other documents within the coverage area.





Information:

PDF Document
Coverage:

Queensland

Author:

NRM-Q

Publisher:

Queensland Government

Published:

9 Mar 2003