MSB No. 070 Franna mobile cranes- uncontrolled movement
Franna Mobile Cranes
-
Click a tab to view specific information about this listing...
- COMPLIANCEgate
Information:
What
A 12t Franna crane was observed rolling backwards from where it had been parked. It came to rest when the rear of the crane impacted a building after traveling a distance of 27m.
Why
When dismounting the cabin the driver probably knocked the Reserve Air switch on. This switch is designed to override the park brake so that the crane can be moved in an emergency if the crane’s engine cannot be started.
Recommendations
Recommendations relate to changing the black Reserve Air switch that has a Push/Lock action to a green Emergency Park Brake Release switch that has a Push/Hold action.
Organisation:
Department of Industry and Resources
Click here to view details and other documents from Department of Industry and Resources.
Jurisdiction:
Relates to Western Australia (WA)